FAQ

Frequently asked questions

What is the importance of oxygen in biology?

Oxygen is the most important molecule to sustain life. Cells survive and thrive in a precise oxygen environment, and low oxygen or hypoxia is a hallmark of many pathologies.

How can oxygen imaging advance cancer therapies?

Hypoxia is known to be an impediment to the success of radiation therapy in cancer. By mapping partial oxygen pressure (pO₂) maps, one can choose which areas require higher radiation dose (e.g., HF10 or below) and avoid the areas which does not require higher dose, thus reducing the overall radiation dose and post-care complications.

Can oxygen imaging be used beyond cancer?

Yes, oxygen is important in many pathologies and is an effective response to treatment. Knowledge of oxygen can improve therapies in type I diabetes, cell and gene therapy, neurological disease, wound healing, ischemia, kidney pathologies, blood transfusion, organ preservation, etc.

What technologies are available for oxygen imaging?

Triarylmethyl (trityl) OXO71-based electron paramagnetic resonance (EPR) oxygen imaging (EPROI) is the leading and only modality that provides quantitative partial oxygen pressure (pO₂) maps in tissue.

What is EPR?

EPR is a magnetic resonance technique that detects unpaired electron spins placed under a constant uniform magnetic field, manipulated by pulse radiofrequency electromagnetic radiation.

What is EPROI?

EPR oxygen imaging (EPROI) is an established noninvasive method to map absolute oxygen. EPROI measures electron spin-lattice relaxation rate (R1) maps of a water-soluble oxygen-reporting trityl OXO71 molecule.

What other physiological parameters can be measured with EPR?

Being EPR uniquely sensitive to unpaired electrons, it allows us to probe paramagnetic species and their environment. In addition to oxygen, EPR probes can also sense local pH, redox potential, inorganic phosphate, etc.

What is the difference between EPROI and BOLD MRI?

Blood oxygen level dependent (BOLD) MRI is a qualitative (not quantitative) technique to probe pO₂. BOLD reports on changes in the relaxation rate R2* of blood as a response to a change in the oxygen demand.

What is the difference between EPROI and F-MISO PET?

Positron emission tomography (PET) with hypoxia-sensitive tracers, such as 18F-Fluoromisonidazole (18F-FMISO), only provides assessment of hypoxia in cells, and does not provide 3D pO₂ maps in the full physiological range.

How is oxygen imaging different from point oxygen measurements?

Oxygen imaging is distinct from pulse oximetry, polarographic electrodes, or oxygen-quenching luminescence sensors, which provide single-point pO₂ values at the location of the probe and do not provide 3D pO₂ maps.

What is JIVA-25®?

JIVA-25® is a first-of-its-kind preclinical oxygen imager, based on EPROI. JIVA-25® provides three-dimensional oxygen maps of tissues, in vitro and in rodents.

Does JIVA-25® give average oxygen, point oxygen, or oxygen maps?

JIVA-25® provides both average oxygen over the sample volume as well as three-dimensional oxygen maps of the sample volume.

Can JIVA-25® measure oxygen in biomaterials?

Yes. JIVA-25® can measure oxygen in various biomaterials so long as there is no paramagnetic component. The examples include, but are not limited to, gelatin, agarose, alginate, etc.

How big should the sample be for the measurements on JIVA-25®?

Samples can be as small as cells in a well or as large as a mouse or a small rat.

Can JIVA-25® perform oxygen imaging in humans?

JIVA-25® is not suitable for oxygen imaging in humans.

What is the magnetic field strength of JIVA-25®?

25 millitesla (mT).

Where can I find publications utilizing JIVA-25®?

You can read publications utilizing JIVA-25® here.

How fast can JIVA-25® measure changes in oxygen?

JIVA-25® standard protocol for acquiring a 3D oxygen map lasts 10 minutes. Acquisition time can be reduced to 2 minutes, at the expense of T1 measurement precision and/or image resolution.

Does penetration depth have an impact on accuracy and sensitivity?

For samples within 40x32 mm, JIVA-25® features volumetric resonators, so penetration depth does not have an impact on accuracy and sensitivity in this case.

Still have questions? Contact us.